Industrial Dehumidifier

AD 270-1700 Industrial Dehumidifier

Desiccant Rotor

Silica gel rotor adsorption dehumidifiers designed for mid-scale industrial process and storage applications. With a self-regulating PTC electric regeneration system and AISI 304 stainless steel housing, they deliver continuous humidity control from −20°C to +40°C across a wide airflow range from 270 m³/h to 1,700 m³/h.

Max. Capacity
8.95kg/h
Operating Range
−20 / +40°C
Models
6models
🔩AISI 304 Stainless Steel HousingElectric Regeneration🌡−20°C / +40°C
AD 270-1700 industrial desiccant rotor dehumidifier
Operating Principle

Adsorption Technology

AD series units operate on an adsorption principle using two separate air streams. Process air passes through the silica gel rotor; the silica gel absorbs water vapour from the air, drying it. As the rotor slowly turns, regeneration air is directed in the opposite direction: heated to +100°C by electric heaters, this airstream strips the absorbed moisture from the rotor, restoring its initial adsorption capacity. The moisture-laden regeneration air is then discharged to the outside.

Desiccant rotor adsorption and regeneration airflow principle
Process airProcess Air
Wet airWet Air
Dry airDry Air
Reactivation airReactivation Air
01
Process Air Inlet

Humid air passes through a G3 filter and is directed to the silica gel rotor; the fan drives the airstream using negative pressure.

02
Adsorption

The silica gel rotor adsorbs water vapour from the process air; the dried airstream is delivered to the process or conditioned space.

03
Regeneration

PTC electric heaters raise regeneration air temperature to ~100°C; this hot airstream passes through the rotor in the opposite direction, stripping and expelling moisture.

04
Continuous Cycle

The rotor slowly rotates between adsorption and regeneration zones, providing uninterrupted dehumidification.

Technical Construction

Materials & Structural Features

Housing

AISI 304 stainless steel; high resistance to corrosive environments and industrial process conditions. Top panel is removable for maintenance.

Silica Gel Rotor

High-efficiency silica gel rotor with a honeycomb structure of corrugated heat-resistant sheets, providing a large adsorption surface and low air pressure drop. Operates undamaged in saturated air conditions; non-combustible and non-flammable.

Drive System

Gearmotor and belt drive system; rotates the rotor at a slow, stable speed. Rotor shaft is fitted with ball bearings and manufactured from steel.

Regeneration Heater

Self-regulating PTC element electric heating coil; maintains constant surface temperature and maximises energy efficiency.

Fans

Process and regeneration fans directly coupled to IP55 / ISO F class single-phase or EC motors. Manual speed adjustment via potentiometer available on AD420 and above.

Filters

Separate G3 filters on both process air and regeneration air inlets.

Electrical Panel

Panel compliant with European standards; main switch, integrated humidity sensor and display, manual/automatic mode.

Connections

Standard spiral duct compatible connections; process air inlet, dry air outlet, regeneration air inlet and wet air outlet.

Full Technical Specifications

Model-by-Model Technical Data

Model ComparisonSelect the models you want to compare
6 / 6 selected

* Capacity values measured at 20°C / 60% relative humidity.

ParameterAD-270AD-420AD-700AD-820AD-1250AD-1700
Capacity (kg/h)*0.992.172.584.325.548.95
Process Airflow270 m³/h420 m³/h700 m³/h820 m³/h1,250 m³/h1,700 m³/h
Process Static Pressure340 Pa360 Pa300 Pa100 Pa230 Pa260 Pa
Process Fan Power138 W157 W170 W170 W440 W720 W
Regeneration Airflow50 m³/h90 m³/h135 m³/h210 m³/h270 m³/h420 m³/h
Regen. Static Pressure135 Pa100 Pa130 Pa210 Pa130 Pa140 Pa
Regen. Fan Power85 W175 W175 W175 W175 W190 W
Drive Motor Power3.0 W3.0 W3.0 W3.0 W3.0 W3.0 W
Regeneration TypeElectricElectricElectricElectricElectricElectric
Installed Power1.75 kW2.6 kW3.5 kW6.6 kW6.6 kW13.2 kW
Heating Coil Temp. Rise75°C85°C90°C105°C85°C105°C
Power Supply230V/1/50Hz230V/1/50Hz230V/1/50Hz400V/3+N/50Hz400V/3+N/50Hz400V/3+N/50Hz
Max. Power Consumption1.97 kW2.93 kW3.84 kW6.95 kW7.22 kW14.12 kW
Max. Current6.6 A12.7 A12.9 A12.6 A13.6 A21.0 A
Sound Pressure Level47 dB(A)49 dB(A)51 dB(A)64 dB(A)69 dB(A)70 dB(A)
Sound Power Level75 dB(A)77 dB(A)79 dB(A)92 dB(A)97 dB(A)98 dB(A)
Operating Temperature−20°C / +40°C−20°C / +40°C−20°C / +40°C−20°C / +40°C−20°C / +40°C−20°C / +40°C
Dimensions (A×B×C)407×450×428 mm475×609×509 mm475×609×509 mm581×745×740 mm581×745×740 mm710×1150×860 mm
Weight23 kg35 kg37 kg57 kg62 kg118 kg
Process Air InletØ125 mmØ200 mmØ200 mmØ250 mmØ250 mmØ315 mm
Dry Air OutletØ125 mmØ200 mmØ200 mmØ250 mmØ250 mmØ315 mm
Regen. Air InletØ125 mmØ160 mmØ160 mmØ160 mmØ160 mmØ200 mm
Wet Air OutletØ80 mmØ125 mmØ125 mmØ160 mmØ160 mmØ200 mm

Request Product Selection Support

Share your process conditions and our engineering team will help you select the correct model, airflow and regeneration configuration.